Intelligent Modules are designed to provide a level of smoke and accurate temperature existing in the ambient air along with its address.
Intelligent Modules
I-9300 | Datasheet |
Overview Addressable Input Module - Monitors switch contacts of remote equipment - Loop powered - Inputs programmable for NO or NC contacts (Programmable via P9910B handheld programmer) |
|
I-9300S | Datasheet |
Overview Addressable Input Interface - Input interface for connecting non-addressable initialization device into GST intelligent system - Small in size suitable to be inserted into back box - Electronically addressed |
|
I-9301 | Datasheet |
Overview Addressable Single I/O Module - Addressable output module - Optional dry contact output or active 24VDC output - Loop powered for relay application |
|
I-9301S | Datasheet |
Overview Addressable Output Interface - Output interface for connecting non-addressable output device into GST intelligent system - Small in size suitable to be inserted into back box - Electronically addressed |
|
I-9303 | Datasheet |
Overview Addressable Dual I/O Module - Addressable I/O with 24V / 3Amp relay output contacts with 2 independent circuits - Input can be configured as NO / NC or self confirmation of output - Two part plug-in construction with base mounted termination |
|
C-9503 | Datasheet |
Overview Addressable Loop Isolator - Isolates faulty part of the loop in the event of a short circuit - Automatically reset once the fault has been cleared - LED status indicator |
|
C-9504E | Datasheet |
Overview Addressable Base Mount Short Circuit Isolator - Replaces standard detector base (DZ-03) - Cost effective installation without the need for additional cabling - Features as per C-9503E |
|
DC-9504E | Datasheet |
Overview Addressable Base Mount Isolator - In the event of a short circuit isolates faulty parts of the loop - Automatically resetting once the fault has cleared - Compatible with digital range of detector |
|
I-9319 | Datasheet |
Overview Addressable Zone Monitor Unit - Interfaces with conventional fire detection equipment/panels etc - Can connect up to 15 detectors with Active EOL or up to 25 detectors with Resistor EOL - Ideal for integrating Sprinkler Zone Valve and Flow Switches |
|
C-9314P | Datasheet |
Overview Passive Remote Indicator - Remote indicator for direct connection to detector via remote indicator terminals - Compatible with Intelligent and Conventional series detectors |
|
DI-9309 | Datasheet |
Overview Addressable Multi-Channel Interface - Cable monitoring for fault of short circuit and open circuit - Interface board for plant monitoring and control - Multi channel integrated for savings installation cost |
|