Intelligent Category
GST-IFP4M | Datasheet |
![]() | Overview UL Intelligent Fire Alarm Control Panel - 7-inch Touch Screen 800 x 480 - 242 addressable devices per loop mixing various types of devices, Max. 1452 addresses - Support USB dongle for securing project database |
GST-M200 | Datasheet |
![]() | Overview UL Intelligent Fire Alarm Control Panel - Single loop fire alarm control panel listed by UL - Loop capacity: 230 intelligent devices for 1st loop, 242 devices for 2nd loop - 2 Style Y Notification Appliance Circuits (NAC) |
I-9102 | Datasheet |
![]() | Overview UL Intelligent Photoelectric Smoke Detector - Aesthetically pleasing low profile design - 8 Bit intelligent processor with A/D converter - Built in algorithm maps for false alarm rejection - Limited stocks |
I-9103 | Datasheet |
![]() | Overview UL Intelligent Rate of Rise and Fixed Temperature Heat Detector - Aesthetically pleasing low profile design - 8 Bit intelligent processor with A/D converter - Fixed temperature and rate of rise heat detection - Limited stocks |
DI-M9101 | Datasheet |
![]() | Overview UL Intelligent Combination Heat Photoelectric Smoke Detector - Address can be set in field - Fault self-diagnostic - Built-in MCU can store 14 history messages |
DI-M9102 | Datasheet |
![]() | Overview UL Intelligent Photoelectric Smoke Detector - Fault self-diagnostic - A magnet test available - Built-in microprocessor stores 14 history data |
DI-M9103 | Datasheet |
![]() | Overview UL Intelligent Rate of Rise and Fixed Temperature Heat Detector - Address can be set in field - Fault self-diagnostic - Rate of rise and fixed temperature, and fixed temperature programmable |
DI-M9204 | Datasheet |
![]() | Overview UL Digital Manual Call Point - Re-settable (non-breaking glass) via special key - Advanced digital communication - Electronically addressed |
C-9503 | Datasheet |
![]() | Overview UL Intelligent Loop Isolator - Isolates faulty part of the loop in the event of a short circuit - Automatically reset once the fault has been cleared - LED status indicator |
C-M9503 | Datasheet |
![]() | Overview UL Intelligent Loop Isolator - Polarity-sensitive external connections. Inputand output can be used inversely without direction - Delayed power-up to output end devices, avoids strong transient current when the load is heavy - Plug-in structure - Limited stocks |
I-M9300 | Datasheet |
![]() | Overview UL Addressable Input Module - Loop power for contact input - Used as interface with conventional detectors and additional 24VDC is required - Connection mode can be set by handhold programmer (P-9910B) - Limited stocks |
I-M9301 | Datasheet |
![]() | Overview UL Addressable Output Module - Single output module - Loop powered for dry contact relay output. Additional 24VDC is required for power output - Connection mode can be set by handhold programmer (P-9910B) - Limited stocks |
DC-M9504 | Datasheet |
![]() | Overview UL Base Mount Isolator - Isolation of short circuit, automatic restore when shortcircuit is cleared - Standards: UL864, NFPA [70,72] |
C-9318 | Datasheet |
![]() | Overview UL Gas Extinguishing Warning Indicator - Polarized two-wire with power cable - Several highlight red LED as background light, which is eye-catching, life-long and low voltage consumption. |
BP-9314P | Datasheet |
![]() | Overview Back Plate for C-9314P - As an accessory for C-9314P Passive Remote - Used to connect C-9314P with a back box when embedded mounting is adopted. |